Star Micronics LC24-15 Reset all tab stops, Horizontal tab, Relative horizontal tab, Esc “R”

Models: LC24-15

1 133
Download 133 pages 7.92 Kb
Page 72
Image 72
Reset all tab stops

Reset all tab stops

Mode

ASCII

Decimal

Hexadecimal

IBM

<ESC> “R”

27 82

1B 52

Resets the horizontal tab stops to their power-up values in which a tab stop is set every 8 column starting at column 9. Also clears all vertical tab stops.

Horizontal tab

Mode

ASCII

Decimal

Hexadecimal

Both

<I-IT>

9

09

Moves the print position to the next horizontal tab stop. Ignored if there is no next horizontal tab stop in the current line. Note that when underlining is selected, spaces skipped by horizontal tabulation are not underlined.

Relative horizontal tab

Mode

ASCII

 

 

 

Decimal

 

Hexadecimal

Std.

cESC>

“I’

nl

n2

27

92

nl

n2

1B

5C

nl

n2

IBM

<FS>

‘T’

nl

n2

28

92

nl

n2

1C

5C

nl

n2

Moves the print position right or left a specified distance (maximum 1440 dots). Ignored if the resulting position is beyond the right or left margin. The formulas for the distance and direction are as follows:

If n2 is between 0 and 63, the print head moves right by (nl + n2 x 256) dots.

If n2 is between 64 and 127, the print head moves left by (nl + [n2- 641 x 256) dots.

Relative horizontal tab in inches

Mode

ASCII

Decimal

Hexadecimal

Both

cESC> “d” nl n2

27 100 nl n2

1B 64 nl n2

Sets the next print position to (nl + n2 x 256)/120 inches from the current position. Ignored if this position is beyond the right margin. The maximum position is 13.6 inches.

64

Page 72
Image 72
Star Micronics LC24-15 Reset all tab stops, Horizontal tab, Relative horizontal tab in inches, Esc “R”, I-It