B-2. Serial Interface Type

ON

OFF

No. 1 2 3 4 5 6 7 8

DIP-SW1

ON

OFF

No. 1 2 3 4

DIP-SW2

 

DIP-SW 1

Switch 1-1

 

Command emulation

ON

 

Star Mode

OFF

 

ESC/POS Mode

 

 

 

All factory settings for dipswitch 1 on the auto cutter model are set at [ON]. Switch 1-3 on the tear bar model is set at [OFF], and the others are set at [ON].

The functions of switches 1-2 through 1-8 will change according to the command emulation that has been set using switch 1-1.

(1) Star mode

 

 

Switch

Function

 

ON

OFF

 

 

 

 

 

 

 

 

 

1-1

Command emulation

 

Always ON

 

APPENDIX

 

 

 

 

 

 

 

1-2

Should not be changed (Should be set to on)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1-3

Auto cutter

 

Valid

Invalid

 

 

 

 

 

 

 

 

 

1-4

Sensor adjustment

 

Invalid

Valid

 

 

1-5

Should not be changed (Should be set to on)

 

 

 

 

 

 

 

 

 

 

 

1-6

Handshaking conditions

 

Offline or receive

Receive buffer full

 

 

 

 

(conditions for BUSY)

 

buffer full

 

 

 

1-7

Automatic status back function

 

Invalid

Valid

 

 

 

 

 

 

 

 

 

1-8

Should not be changed (Should be set to on)

 

 

 

 

 

 

 

 

 

(2) ESC/POS mode

Switch

Function

 

ON

OFF

 

 

 

 

 

1-1

Command emulation

 

Always OFF

 

 

 

 

 

 

1-2

Graphic Adjustment

 

203 DPI

180 DPI

 

 

 

 

 

1-3

Auto cutter

 

Valid

Invalid

 

 

 

 

 

1-4

Sensor adjustment

 

Invalid

Valid

 

 

 

 

 

1-5

Should not be changed (Should be set to on)

 

 

 

 

 

 

 

1-6

Handshaking conditions

 

Offline or receive

Receive buffer full

 

(conditions for BUSY)

 

buffer full

 

 

 

 

 

 

1-7

Automatic status back function

 

Invalid

Valid

 

 

 

 

 

1-8

Should not be changed (Should be set to on)

 

 

 

 

 

 

 

– 101 –