Star Micronics TSP600 Appendix E Periheral Unit Drive Circuit, Peripheral Drive Connector

Models: TSP600

1 113
Download 113 pages 29.27 Kb
Page 111
Image 111

Appendix E: Periheral Unit Drive Circuit

Peripheral unit drive circuit connector only connects to peripheral units such as cash drawers, etc.

Do not connect it to a telephone.

Use cables which meet the following specifications.

Peripheral Drive Connector

Pin No.

Signal

Function

I/O

 

 

name

direction

 

 

 

 

 

 

1

FG

Frame ground

 

 

 

 

 

 

 

 

2

DRD1

Drive signal 1

OUT

 

 

3

+24V

Drive power

OUT

 

 

 

 

 

 

 

 

4

+24V

Drive power

OUT

 

 

 

 

 

 

 

 

5

DRD2

Drive signal 2

OUT

6

1

6

DRSNS

Sense signal

IN

<Viewed from Connector Surface>

Modular plug

Modular plug: MOLEX 90075-0007,

 

AMP641337, or BURNDY B-66-4

Shield

 

 

Wire lead

6

 

1

 

APPENDIX

Notes: 1. Pin 1 must be shield drain wire connected to peripheral device frame ground.

2.It is not possible to drive two drives simultaneously.

3.The peripheral drive duty must satisfy the following: ON time / (ON time + OFF time) 0.2

4.The resistance of the peripheral drive solenoid must be 24 Ω or

higher.

If it is lower than 24 Ω, over-current may flow into the solenoid, causing the solenoid to burn.

– 108 –

Page 111
Image 111
Star Micronics TSP600 user manual Appendix E Periheral Unit Drive Circuit, Peripheral Drive Connector, Modular plug