The following is the procedure for changing the settings on DIP switch No. 3.

1.Turn off the printer and all components connected to it.

2.Remove the 2 screws.

3.Remove the serial interface board unit.

4.Change the setting of the DIP switches.

5.Replace the serial interface board unit. Then secure it with the screws.

6.Turn on the printer and all components connected to it.

APPENDIX

ON

OFF No. 1 2 3 4 5 6 7 8

DIP-SW3

The factory settings of DIP switch are all on, except for switches 7 and 8.

DIP-SW 3

Switch

 

Function

 

ON

OFF

 

 

 

 

 

 

 

 

3-1

 

Baud Rate

 

 

See table below

 

 

 

 

3-2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3-3

 

Data Length

 

8 bits

7 bits

 

 

 

 

 

 

3-4

 

Parity Check

 

Disabled

Enabled

 

 

 

 

 

 

3-5

 

Parity

 

Odd

Even

 

 

 

 

 

 

3-6

 

Handshake

 

DTR/DSR

XON/XOFF

 

 

 

 

 

3-7

Pin #6 (DSR) reset signal

 

Valid

Invalid

 

 

 

 

 

3-8

Pin #25 (INIT) reset signal

 

Valid

Invalid

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Baud Rate

 

Switch 3-1

 

 

Switch 3-2

 

 

 

 

 

 

 

 

4800BPS

 

OFF

 

 

ON

 

 

 

 

 

 

 

 

9600BPS

 

ON

 

 

ON

 

 

 

 

 

 

 

 

19200BPS

 

ON

 

 

OFF

 

 

 

 

 

 

 

 