Star Trac 7600, 7700 manual Parameter Setting Definitions

Models: 7700 7600

1 68
Download 68 pages 46.28 Kb
Page 30
Image 30

Parameter Setting Definitions

The following are the definitions of each parameter from the Maintenance Mode.

UNITS: Sets the conversion for speed, distance and weight between US and Metric measurements. (Conversions: Km = Miles x 1.6 ￿ Lb = Kg x 2.2)

MINIMUM SPEED: Sets the minimum start up speed for the unit. MAXIMUM SPEED: Sets the maximum speed available for the unit.

ELEVATION: Turns the elevation (incline) system on or off.

TIME: Sets the maximum workout time for the unit. Can be used in a high-use facility or location that wishes to limit usage times of a unit.

OPER HOURS: The accumulation of hours the unit has been used1 DISTANCE: The accumulation of miles the unit has been used1,2

WEIGHT: Sets the default weight, usually 155 lbs (70 kg) that the unit will use to calculate calories to be used if a user does not enter their weight during workout setups.

SERIAL NO: The last few numbers of the unit serial number. *May or may not be used1

LANGUAGE: Sets the language that the display will show.

ENTRY: Sets how the numbers will be entered during key strokes: (UNITS = 1.0 increments, TENTHS = 0.1 increments)

HEART RATE: Sets the type of Heart Rate to use: (POLAR only, CONTACT only or BOTH). METS: Used for workout feedback. *Consult an Owners Manual or a certified trainer

for definition.

WATTS: Used for workout feedback. *Consult an Owners Manual or a certified trainer for definition.

PAUSE: Sets the amount of time in seconds that a unit will pause when the side stop switch or the stop key is pressed during a workout.

SCALE: Turns the scale feature on or off.

INFRARED COM: Turns the infrared communication system on or off. CSAFE: Turns the CSafe power outlets on or off.

FAN: Turns the fan system on or off.

AUTO STOP: *Not used at this time. Be sure this parameter is set to OFF. ENTERTAINMENT: Turns the entertainment system on or off.

ACCELERATION Sets the amount of time the unit will take (in seconds) to go from 0.0 mph to TIME: achieve the maximum speed as set in the MAXIMUM SPEED parameter.

DECELERATION Sets the amount of time the unit will take (in seconds) to go from the maximum TIME: speed as set in the MAXIMUM SPEED parameter down to 0.0 mph.

LOCK OUT: Used to disable use of the unit unless the LOCK OUT ID has been entered. LOCK OUT ID: A number combination used to lock out the display from use.

Footnotes: 1 When replacing a display electronic board, it is a good idea to write down this number and set it into the new electronic board to help keep accurate records of parameters with the unit.

2When resetting the Rewax Belt message (LAST DECK parameter), this is the number that will automatically be copied into the LAST DECK parameter to set the current mileage.

28

Service Manual: E-TR and E-TRi

Page 30
Image 30