Star Trac 7700, 7600 manual Csafe Test

Models: 7700 7600

1 68
Download 68 pages 46.28 Kb
Page 35
Image 35

CSAFE TEST

This parameter is used by Star Trac at the factory.

HEART RATE TEST

The Heart Rate Test mode can be used to simultaneously test the function and response for both the contact and Polar heart rate systems.

￿ Press ‘Start’ key

Display will read POLAR 0 CONTACT 0

￿ ￿ Grab the HR grips

CONTACT X should detect your heart rate then display the reading

(If applicable) Polar strap

*If you have a Polar transmitter or a polar signal simulator then signal will be detected

 

and processed by the Polar system and display the value as POLAR X

￿Press ‘Stop’ key twice to return to the MAINTENANCE MODE

INFRARED TEST

This parameter is used by Star Trac at the factory.

LAST ERROR LIST

The Last Error List is a list bank of the last five issues the unit has captured into its memory for diagnosis of an issue. To access the Last Error list banks, follow the procedure below. For more information including DFR, see the DFR section in this manual.

￿ Press ‘Start’ key

Display will enter DISPLAY TEST and await your next command

￿ Press ‘Start’ key

Display will cycle thru a self test and display all led’s in a sequenced pattern

￿Press ‘Stop’ key twice to return to the MAINTENANCE MODE

￿ Press ‘Start’ key

Display will enter DISPLAY TEST and await your next command

￿ Press ‘1’ key

MC1 Vx.x CKSM xxxx will display

￿

 

￿ Press ‘Speed Plus’ key

MC2 Vx.x CKSM xxxx will display

￿ Loop

￿ Press ‘Speed Minus’ key

MC1 Vx.x CKSM xxxx will display

￿

 

￿Press ‘Stop’ key twice to return to the MAINTENANCE MODE

￿ Press ‘Start’ key

Display will enter DISPLAY TEST and await your next command

￿ Press ‘2’ key

Display will read KEYBOARD TEST

￿Press any key except ‘Stop’ to verify function.

￿Press ‘Stop’ key to verify function then press again to return to the MAINTENANCE MODE

When opening the banks, #1 is the first code that was captured, #2 the second, #3 the third and so on. If more than 5 codes have been captured, bank #5 will always be the latest code captured and the previous number will be replaced accordingly.

For a list of definitions for the Last Error List, see the LAST ERROR LIST DEFINITIONS section in this manual.

33

Service Manual: E-TR and E-TRi

Page 35
Image 35
Star Trac 7700, 7600 manual Csafe Test