ERROR | NAME | DESCRIPTION |
| DIAGNOSIS |
CODE |
|
|
|
|
39 | Speed calibra- | Fit CPU reports MCB error | 1. | |
| tion value out of | status: Speed calibration | 2. | If the problem persists, check the Product Model in |
| range | value out of range | ||
|
| Maintenance Mode and ensure it is correct. | ||
|
|
|
| |
|
|
| 3. | |
|
|
|
|
|
40 | Speed lost | Fit CPU reports MCB error | 1. | |
| (RPM Sensor) | status: Speed lost (RPM | 2. | If the problem persists, check the Product Model in |
|
| Sensor) | ||
|
|
| Maintenance Mode and ensure it is correct. | |
|
|
|
| |
|
|
| 3. | |
|
|
| 4. | If the problem persists check the speed sensor. Ro- |
|
|
|
| tate the flywheel on the motor and ensure that the |
|
|
|
| speed sensor LED on the MCB blinks as the flywheel |
|
|
|
| is moving. |
|
|
|
|
|
41 | Incline feedback | Fit CPU reports MCB error | 1. | |
| out of range | status: Incline feedback out | 2. | If the problem persists, check the Product Model in |
|
| of range |
| Maintenance Mode and ensure it is correct. |
|
|
|
| |
|
|
| 3. | |
|
|
| 4. | If the problem persists, check to see that the Incline |
|
|
|
| Counts value in the Incline Calibration Screen is |
|
|
|
| changing during incline calibration. The Incline Counts |
|
|
|
| should go down as the elevation goes up. |
|
|
| 5. | If the Incline Counts is not changing during calibration, |
|
|
|
| then the cable from the elevation motor to the MCB |
|
|
|
| should be checked. If the cable is OK then the eleva- |
|
|
|
| tion motor should be replaced. |
|
|
|
|
|
42 | Incline stuck | Fit CPU reports MCB error | 1. | |
|
| status: Incline stuck | 2. | If the problem persists, check the Product Model in |
|
|
| ||
|
|
|
| Maintenance Mode and ensure it is correct. |
|
|
| 3. | |
|
|
| 4. | If the problem persists, check to see that the Incline |
|
|
|
| Counts value in the Incline Calibration Screen is |
|
|
|
| changing during incline calibration. The Incline Counts |
|
|
|
| should go down as the elevation goes up. |
|
|
| 5. | If the Incline Counts is not changing during calibration, |
|
|
|
| then the cable from the elevation motor to the MCB |
|
|
|
| should be checked. If the cable is OK then the eleva- |
|
|
|
| tion motor should be replaced. |
255 | emergency stop | Fit CPU detected emer- | 1. | Reset the |
| condition | gency stop condition |
| operational again. |
|
|
| 2. | If the problem persists, check the cables/connections |
|
|
|
| in the Hot Bar. Also check the |
|
|
|
| Hot Bar that plugs into the FitCPU. |
|
|
| 3. | If the problem still persists check the communications |
|
|
|
| cable between the FitCPU and the Translator Board. |
|
|
| 4. | If all of the above is OK then replace the Translator |
|
|
|
| Board. |
40