TROUBLESHOOTING SBD WATER HEATERS

SBD TANK TYPE HEATERS

SERVICE HANDBOOK

TROUBLESHOOTING SBD WATER HEATERS

To troubleshoot a SBD water heater check that:

120 VAC is supplied to the heater

the tank is full of water

gas is supplied to the unit

STEP 1

TEST THE TRANSFORMER

STEP 1 - TO TEST THE TRANSFORMER - Using a multimeter, test for 24 VAC between the secondary transformer terminals.

IF

THEN

The meter does not read 24 VAC:

Check that the 120 VAC is supplied

 

from the On/Off Switch – if not, replace

 

switch.

 

Check that the 120 VAC is supplied

 

from transformer.

The meter reads 24 VAC:

Go to step 2.

Technical Training Department

19

Ashland City, TN ©2003

Page 20
Image 20
State Industries SBD85 500, SBD71 120 manual Troubleshooting Sbd Water Heaters, Step, Test The Transformer, Then