STEP 14A

SBD TANK TYPE HEATERS

SERVICE HANDBOOK

STEP 14A

PILOT VALVE - OHM TEST

SBD 120 – 400 GAS VALVE

STEP 14A. PILOT VALVE - OHM TEST. If pilot assembly is sparking but no pilot flame is established, disconnect the pilot valve solenoid leads. Using a multimeter, (set to read ohms) test for 20* ohms resistance +/- 5 through the solenoid coil.

IF

THEN

The meter dose not read 20 ohms plus or

Replace gas valve

minus 5:

 

 

The meter does read 20 ohms plus or

Gas valve should work. Also check that

minus 5:

 

pilot gas is present and pilot tube or

 

 

orifice are not blocked