HIGH LIMIT, LEFT TERMINAL TEST

SBD TANK TYPE HEATERS

SERVICE HANDBOOK

STEP 2

HIGH LIMIT, LEFT TERMINAL TEST

Ground

24VAC

FM Transformer

STEP 2. HIGH LIMIT, LEFT TERMINAL TEST. Test for 24 VAC between the left high limit terminal and ground.

IF

THEN

The meter does not read 24 VAC:

Check wiring between transformer and

 

 

high limit.

The meter reads 24 VAC:

Go to Step 3.

Note: The high limit (Energy Cut Off) opens if the tank water temperature exceeds 205 degrees. The control is resettable (manually) when the tank water temperature drops below 185 degrees.