State Industries SBD85 500 TROUBLESHOOTING THE EFFIKAL DAMPER continued, Service Switch, Then

Models: SBD85 500 SBD71 120

1 56
Download 56 pages 57.8 Kb
Page 30
Image 30
TROUBLESHOOTING THE EFFIKAL DAMPER (continued)

SBD TANK TYPE HEATERS

SERVICE HANDBOOK

TROUBLESHOOTING THE EFFIKAL DAMPER (continued)

Condition:

Thermostat closed, damper open.

Service Switch

Damper

Open

Damper

Auto

STEP 9B

A1 IS CORRECT, CHECK SERVICE SWITCH POSITION

IF

THEN

Switch is incorrect position

Replace damper board/motor assembly.

Switch is not in correct position

Adjust switch

 

Cycle thermostat to verify that damper

 

 

operation is correct.

Technical Training Department

29

Ashland City, TN ©2003

Page 30
Image 30
State Industries SBD85 500 TROUBLESHOOTING THE EFFIKAL DAMPER continued, A1 IS CORRECT, CHECK SERVICE SWITCH POSITION