State Industries SBD85 500, SBD71 120 Pc Board Motor Test, Service Switch, Motor Lead, Step, Then

Models: SBD85 500 SBD71 120

1 56
Download 56 pages 57.8 Kb
Page 24
Image 24
PC BOARD MOTOR TEST

SBD TANK TYPE HEATERS

SERVICE HANDBOOK

STEP 6

PC BOARD MOTOR TEST

Service Switch

Motor Lead

 

Motor Lead

 

 

 

 

 

 

STEP 6. PC BOARD/MOTOR TEST. Check for 24 VAC between the two motor lead terminals of the PC board. Disconnect the wires for this test.

IF

THEN

24 VAC is not present:

Replace the Damper Drive (part #

 

 

194484) and go to step 7. The board

 

 

and relay are one piece. Regardless of

 

 

which part is defective, both parts

 

 

should be changed.

Voltage is present:

This verifies that the motor is receiving

 

 

power but not closing the damper.

 

Replace the Damper Drive and go to

 

 

step 7.

Note: The service switch may be used to bypass the damper, while waiting for a replacement part.

WARNING - In the event of damper motor failure, verify that the damper is in the "open" position before utilizing the service switch

Technical Training Department

23

Ashland City, TN ©2003

Page 24
Image 24
State Industries SBD85 500 Pc Board Motor Test, Service Switch, Motor Lead, Step, Sbd Tank Type Heaters Service Handbook