S U F S E R V I C E H A N D B O O K

O P E R A T I O N

CONTROLS

NORMAL INDICATIONS / READINGS / SETTINGS

During Call for Heat

• On/Off switch in the “on” position

DISPLAY PANEL (CONTROL PANEL)

Water Temperature F° — current average tank water temperature displayed

120 VAC LED light on

24 VAC LED light on

High Limit/Vent Switch LED light on

Blower (while blower is running) LED light on

Air Pressure Switch (while blower is running) LED light on

Control Status LED light on

Gas Valve (during ignition period and heating cycle) LED light on

The water temperature inside the tank must be below the current temperature setting to activate a call for heat. Pressing the Set/Reset button approximately 4 – 6 seconds after powering up the water heater will reveal the current temperature setting. See the instructions below for how to view or change temperature settings.

Technical Training Department

16