S U F S E R V I C E H A N D B O O K

T R O U B L E S H O O T I N G

PRESSURE SWITCH CONTINUITY

STEP 7

PRESSURE SWITCH CONTINUITY TEST

STEP 7: CHECK FOR CONTINUITY BETWEEN PRESSURE SWITCH TERMINALS WITH WIRES REMOVED.

Condition:

On/Off switch is off.

All wires are disconnected from all pressure switches.

Multimeter is set to lowest ohms scale.

IF…

THEN

 

 

 

 

blocked inlet switch does not show continuity

replace switch.

 

 

blocked inlet switch does show continuity

continue.

 

 

blower proving switch does show continuity

replace switch.

 

 

blower proving switch does not show continuity

continue.

 

 

 

check for minimum supply gas

 

pressure of

low gas pressure switch does not show continuity

5.0” W.C. natural gas

9.0” W.C. LP gas

 

 

replace switch if gas pressures

 

are above these minimums.

 

 

low gas pressure switch does show continuity

continue.

 

 

blocked outlet pressure switch does not show continuity

replace switch.

 

 

blocked outlet pressure switch does show continuity

reconnect all wires to pressure

switches; continue to Step 8.

 

 

 

Technical Training Department