S U F S E R V I C E H A N D B O O K

T R O U B L E S H O O T I N G

BLOWER

STEP 8

120 VAC TO BLOWER

STEP 8: CHECK FOR 120 VAC TO BLOWER FROM CN2 PLUG PIN 1 AND 2. Condition:

Reconnect all plugs to control board.

On/Off switch is on.

Call for heat is activated.

Insert meter probes into back of CN2 plug on pins 1 and 2 with CN2 plugged in, power on, and a call for heat activated.

IF…

AND

THEN

 

 

 

 

 

 

120 VAC is not

 

replace the control board if call for heat is active and Step 7 has been

present

 

performed and results were successful — continue to Step 9A.

 

 

 

State Water Heaters

25

Technical Training Department

Ashland City, Tennessee © 2004