TRANSFORMER

STEP 2

120 VAC TO TRANSFORMER

STEP 2: CHECK FOR 120 VAC TO TRANSFORMER FROM PIN 1 AND 2 ON CONTROL BOARD CN4 TERMINAL.

Condition:

Disconnect CN4 plug from control board.

On/Off switch is on.

Check for 120 VAC between pin 1 and 2 at CN4 on the control board as illustrated above. Perform this test with the CN4 plug disconnected and the On/Off switch turned on.

IF…

 

THEN

 

 

 

 

 

 

120

VAC is not present

check CN1 plug connection

replace control board if Step 1 has been performed and results were successful.

 

 

 

 

 

120

VAC is present

reconnect CN4 plug to control board, continue to Step 3.

 

 

 