State Industries STC-077 dimensions Pressure Switches Part Number / Activation PRESSURE†

Models: STC-077

1 46
Download 46 pages 13.03 Kb
Page 35
Image 35

S U F S E R V I C E H A N D B O O K

C O M P O N E N T I N F O R M A T I O N

PRESSURE SWITCHES (CONTINUED)

PRESSURE SWITCHES

PART NUMBER / ACTIVATION PRESSURE

Model

Blocked Inlet

Blower Prover

Low Gas Pressure

Blocked Outlet

 

Normally Closed

Normally Open

Normally Open

Normally Closed

 

Opens on a fall

Closes on a rise

Closes on a rise

Opens on a rise

 

 

 

 

 

SUF 150

193363-000 / -0.76”

194706-000 / +1.00”

N/A

193362-000 / +2.60”

 

 

 

 

 

 

193355-000 / -1.80”

194706-000 / +1.00”

N/A

193357-000 / +4.00”

 

 

 

 

 

 

193355-000 / -1.80”

194706-000 / +1.00”

N/A

193357-000 / +4.00”

 

 

 

 

 

SUF 199

193363-000 / -0.76”

194706-000 / +1.00”

N/A

193364-000 / +2.87”

 

 

 

 

 

 

193356-000 / -2.00”

194706-000 / +1.00”

N/A

193357-000 / +4.00”

 

 

 

 

 

 

193356-000 / -2.00”

194706-000 / +1.00”

N/A

193357-000 / +4.00”

 

 

 

 

 

SUF 240

193361-000 / -0.77”

194706-000 / +1.00”

191149-005 / +5.20”

193357-000 / +4.00”

 

 

 

 

 

†.Pressure values are given in inches of water column pressure (“W.C.).

Negative pressure values in this table are preceded by a “-” minus sign and indicate pressure below atmospheric; in a vacuum. Positive pressures are preceded by a “+” plus sign and indicate pressure above atmospheric.

Technical Training Department

34

State Water Heaters

STC-077

Ashland City, Tennessee © 2004

Page 35