S U F S E R V I C E H A N D B O O K

T R O U B L E S H O O T I N G

IGNITOR RESISTANCE

STEP 11

IGNITOR RESISTANCE CHECK

STEP 11: CHECK RESISTANCE BETWEEN TWO WIRE CONNECTS AT CN5 IGNITOR PLUG END.

Condition:

On/Off switch is off.

Disconnect CN5 ignitor plug from circuit board.

Multimeter is set to lowest ohms scale above 300 ohms.

IF…

THEN

 

 

 

 

ohms reading taken is not between 50 – 300 ohms

replace the ignitor.

 

 

ohms reading taken is between 50 – 300 ohms

reconnect CN5 plug, continue to Step 12.

 

 