![](/images/new-backgrounds/1057825/5782565x1.webp)
S U F S E R V I C E H A N D B O O K
C O M P O N E N T I N F O R M A T I O N
COMPONENT INFORMATION
FLAME SENSING ROD
PART NUMBER | FLAME SENSING CURRENT | COMMENTS | ||
|
|
| ||
192478 | 0.7 Micro Amp (µ) | SUF 150, 199, & 240 | ||
|
|
|
|
|
HOT SURFACE IGNITOR (HSI) |
|
|
| |
|
|
|
|
|
PART NUMBER | VOLTAGE | AMP | OHMS COLD | COMMENTS |
|
|
|
|
|
192638 | 120 VAC | 1.0 | 50 – 300 | SUF 150, 199, & 240 |
|
|
|
|
|
ORIFICE TABLE
ORIFICE TABLE
SUF MODEL | MAIN BURNER | MAIN ORIFICE SIZE | AIR ORIFICES | AIR ORIFICE | |
ORIFICE NO. | INCHES | PT. NO. | SIZE — INCHES | ||
| |||||
|
|
|
|
| |
|
|
|
|
| |
150 | 0.235 | 0.875 | |||
|
|
|
|
| |
199 | 0.304 | 1.031 | |||
|
|
|
|
| |
240 | 0.360 | 1.196 | |||
|
|
|
|
| |
150 Prop | 0.141” | 0.872 | |||
|
|
|
|
| |
199 Prop | 0.166” | 1.150 | |||
|
|
|
|
|
*
N O T E : Hex head of main burner orifice is upstream end — gas flows out of tapered end.
Technical Training Department | 32 | State Water Heaters |
Ashland City, Tennessee © 2004 |