State Industries STC-077 Troubleshooting, PRE-SERVICE Tips, VAC to Control Board, Check That

Models: STC-077

1 46
Download 46 pages 13.03 Kb
Page 19
Image 19

S U F S E R V I C E H A N D B O O K

T R O U B L E S H O O T I N G

TROUBLESHOOTING

PRE-SERVICE TIPS

CHECK THAT:

Insure 120 VAC power supply has correct polarity — check neutral (white) wire to ground with volt meter. It should read “0” volts.

Tank is full of water

Exhaust and intake vent do not exceed allowable limits

All plugs into boards are secure

Condensate hose is drained and open

Proper (natural or propane) gas is supplied

120 VAC TO CONTROL

STEP 1

120 VAC TO CONTROL BOARD

STEP 1: CHECK FOR 120 VAC TO CONTROL BOARD CN1 TERMINAL. Condition:

Disconnect plug from CN1 terminal.

On/Off switch is on.

Check for 120 VAC black wire terminal white wire on plug.

IF…

 

THEN

 

 

 

 

 

 

120

VAC is not present

check On/Off switch, turn switch on, replace On/Off switch if defective, restore

power to the water heater.

 

 

 

 

 

120

VAC is present

reconnect CN1 plug, continue to Step 2.

 

 

 

 

 

 

Technical Training Department

18

State Water Heaters

STC-077

Ashland City, Tennessee © 2004

Page 19
Image 19
State Industries STC-077 dimensions Troubleshooting, PRE-SERVICE Tips, VAC to Control Board, Check That