Connection Lines
Connections for TO PROCESS and FROM PROCESS lines are 1" NPT (25.4 mm). Water connections for COOLING WATER SUPPLY and COOLING WATER DRAIN are ¾” NPT (19.1 mm); see Section
The manufacturer stocks many lengths of flexible metal hose; the part number is
WARNING! Component failure may result in
Electrical System Controls
The electrical controls of your Upright unit are specially engineered for reliability, safety, and simplicity of operation. Switch functions are clearly labeled. Your Upright unit has a system status board so you can evaluate the status and performance of the unit at a glance. Pilot lights are provided to indicate key unit functions.
An audible alarm is standard with your unit. The alarm will sound in the event of the following conditions:
•motor overload
•safety thermostat trip (over temperature)
•low fluid pressure
•low fluid level
•high fluid level (optional)
Push the ALARM SILENCE button to silence the alarm. See Section
Electrical Panel and System Components
The pump motor and immersion heater operate on
All components are IEC rated for long life and reduced maintenance. The heater elements are branch fused, and protected from contactor welding by a separate primary voltage contactor. The pump motor is controlled by a full voltage magnetic reversing starter, with fused branch circuit overcurrent and thermal overload protection. Many additional features are available as options.
A NEMA 12 enclosure is standard, with NEMA 4 available as an option.
Upright Portable Hot Oil TCUs | Chapter 2: Functional Description | 13 |