Chapter 4: Operation
4-1 Start-up
1.Push the PUMP START button to start the pump.
2.When the unit has built at least five (5) psi (34.5 kPa) of pressure, wait two (2) minutes, then select a set point of 100°F (38ºC) and switch the unit into AUTO mode.
As the oil warms up, viscosity decreases and pressure falls.
3.Four to six inches (4” to 6” / 10 cm to 15 cm) of fluid should be visible in the sight glass.
4.Select a process set point on the controller.
4-2 Controller Description & Operation
The M2B+ controller is an
The controller has been fully factory tested. Set the desired process temperature set point and the controller does the rest.
Refer to the M2B+ Owner’s Manual supplied with your unit for specific operation instructions.
Upright Portable Hot Oil TCUs | Chapter 4: Operation | 24 |