Sterling 682.88107.00 specifications Problem, Possible cause, Corrective action

Models: 682.88107.00

1 49
Download 49 pages 25.44 Kb
Page 37
Image 37

 

Problem

 

Possible cause

 

Corrective action

 

 

 

Loss of fluid in process.

 

Check all lines/connections/

 

 

 

 

fittings.

 

 

 

 

 

 

 

 

Vent valve open.

 

Allow vent timer to run out; or,

 

 

 

 

check valve operation when unit

 

Unit does not heat properly/can

 

 

 

is cold by opening the fill port.

 

 

 

 

Switch to Manual Cool mode

 

not achieve set point.

 

Faulty/dirty solenoid valve;

 

several times to flush valve. If

 

 

 

usually detected when there is a

 

the leak continues, disconnect

 

 

 

steady stream or trickle of water

 

the power to the unit, turn off

 

 

 

out of the drain line.

 

the water supply, and clean or

 

 

 

 

 

replace the solenoid.

 

 

 

Degraded fluid.

Drain and replace fluid.

 

 

 

Defective heater contactor.

 

Visual inspection of coil and

 

 

 

 

contacts. Repair/replace

 

 

 

 

 

defective contactors.

 

 

 

 

 

Check resistance on all three (3)

 

 

 

Defective immersion heater.

 

legs of heater with an ohmmeter.

 

 

 

 

If not all equal, contact factory

 

 

 

 

 

 

 

 

 

 

for replacement heater.

 

 

 

 

 

Check heater tank for scorched/

 

Unit does not heat.

 

 

 

discolored paint. Check

 

 

Heater burnout.

 

resistance on all three (3) legs of

 

 

 

 

 

 

 

 

 

heater with an ohmmeter.

 

 

 

 

 

Replace heater as needed.

 

 

 

 

 

Check the heater output with an

 

 

 

 

 

ohmmeter to ground. It should

 

 

 

Controller heater output open.

 

read in the mega-ohm range.

 

 

 

 

 

Infinite or zero readings indicate

 

 

 

 

 

a defective output.

 

 

 

Clogged Y strainer.

 

Clean Y strainer.

 

 

 

Water supply to unit is turned

 

Open water supply.

 

 

 

OFF.

 

 

 

 

 

 

 

 

 

Water drain is plugged or

 

Clear drain line or eliminate

 

 

 

excessive back pressure in drain

 

 

 

 

 

back pressure condition.

 

 

 

line.

 

 

Unit overheats/unable to cool.

 

 

 

 

 

Heat exchanger tubes plugged

 

Remove tube bundles; clean/

 

 

 

by lime deposits.

 

replace as required.

 

 

 

 

 

Test solenoid valve by switching

 

 

 

Faulty solenoid valve.

 

to Manual Cool mode and listen

 

 

 

 

for valve operation. Replace if

 

 

 

 

 

 

 

 

 

 

faulty.

Upright Portable Hot Oil TCUs

Chapter 6: Troubleshooting

37

Page 37
Image 37