Sterling 682.88107.00 specifications Upright Unit Piping Setup

Models: 682.88107.00

1 49
Download 49 pages 25.44 Kb
Page 21
Image 21
Figure 1: Upright Unit Piping Setup

Figure 1: Upright Unit Piping Setup

Connect the TO PROCESS hookup to the entrance of the process and the FROM PROCESS hookup to the exit of the process. Connect the COOLING WATER SUPPLY to your plant water supply. Connect the COOLING WATER DRAIN line to an open drain, or to the return line of your central water system. If returning to a central water system, use a condensate/return tank to avoid a standing water column on the heat exchanger drain line.

Caution! If you are routing the drain line to an open drain, make sure that the line is directed away from personnel to avoid scalding.

Carefully select connecting lines and connectors between the Upright unit and the process to best meet the needs and requirements of your application.

Make sure lines and connectors have a service rating of at least 100 psig (689.5 kPa/6.9 bars), and a temperature rating at least equal to the maximum operating temperature of your Upright unit.

Note: To prevent debris from fouling reservoir fluid, the Upright unit is equipped with an internal vent on the reservoir tank. Use the plug provided to close off the external fill port after filling the unit with heat transfer fluid.

Upright Portable Hot Oil TCUs