Figure 32: Solenoid Valve Location on Sequence-T Valve & Compressed Air Connections

Solenoid Valve

(1) Normally Closed Port = Exhaust Port

(2) Common = Connect to Valve

(3) Normally Open = Connect to Air Supply

Your 3/8” (9 mm) branch supply line should include:

1.A shutoff valve for ON/OFF control.

2.An air filter/pressure regulator with a gauge for pressure control.

3.Mini-lubricators located at each vacuum receiver.

Running Remote Proportioning Valve or Proportioning Vacuum Receiver Compressed Air Lines

You must run compressed air to any proportioning valves in the system. Refer to the Proportioning Valve operating manual for detailed installation and operation information.

Conveying System Mechanical Components Chapter 3: Installation

65 of 138

Page 65
Image 65
Sterling 882.00379.00 manual Solenoid Valve