Caution! The manufacturer recommends that you protect PLC memory by providing the control panel with a dedicated circuit, a true earth ground, and a spike/surge protector.

Connecting the Control Panel to Vacuum Receivers

Refer to the wiring connection drawings shown on the next page and to your conveying control panel’s diagrams for general connections.

Note: Each control panel is supplied with specific control schematics and a separate Operation and Instruction manual. To ensure proper conveying system operation, install the equipment according to the enclosed instructions.

Wire the Atmospheric/Sequence-T solenoid (SOL) valve to the terminal provided in the conveying system control panel enclosure.

Wire the Bin Full/Hopper Full switch (LS/PRS) to the terminal provided in the conveying system control panel enclosure.

On 115 VAC control voltage systems, run a common hot (115 VAC) wire and a common neutral wire from the controller to each vacuum receiver in the conveying system.

On 24 VDC control voltage systems, run a common +24 VDC wire and a common 0 (zero) VDC wire from the controller to each vacuum receiver in the conveying system.

On all systems, run two wires to each vacuum hopper: one each from the controller to the Bin-Full switch (LS) and to the Atmospheric/Sequence-T solenoid (SOL) valve.

Note:

The conveying system control panel is supplied with a terminal strip

 

at the upper right corner for + positive and negative wire

 

connections.

Be sure the solenoid and proximity switch(s) (if supplied) on vacuum receivers are the same voltage (24 VDC or 115 VAC) as the conveying system control panel control voltage. Consult the control panel serial tag and the solenoid valve nameplates.

Wire size depends on control voltage, distance, number of vacuum receivers, and the number of wires in each raceway. Consult a qualified electrician.

Properly ground each receiver to reduce static build-up generated by material conveying.

Conveying System Mechanical Components Chapter 3: Installation

67 of 138

Page 67
Image 67
Sterling 882.00379.00 manual Connecting the Control Panel to Vacuum Receivers