Machine-Side Hopper Loaders
8.2. Servicing the loader
MDisconnect the unit from main power supply by unplugging it.
Depressurize all system sections of the equipment (only units with active cleaning).
8.2.1.Changing the sealing ring of the outlet flap
1.Open the toggle fasteners (A) and the access door (B) of the hopper loader.
2.Draw the old sealing ring (C) off the nozzle of the material outlet.
3.Install the new sealing ring (C).
F Make sure the new sealing ring (C) | Figure 12: Installation sealing ring |
in installed properly. Do not install |
|
the sealing ring |
|
4. Close the access door (B) and the toggle fasteners (A).
& Order number sealing ring “material outlet”: | |
|