Machine-Side Hopper Loaders

8.2. Servicing the loader

MDisconnect the unit from main power supply by unplugging it.

Depressurize all system sections of the equipment (only units with active cleaning).

8.2.1.Changing the sealing ring of the outlet flap

1.Open the toggle fasteners (A) and the access door (B) of the hopper loader.

2.Draw the old sealing ring (C) off the nozzle of the material outlet.

3.Install the new sealing ring (C).

F Make sure the new sealing ring (C)

Figure 12: Installation sealing ring

in installed properly. Do not install

 

the sealing ring upside-down.

 

4. Close the access door (B) and the toggle fasteners (A).

& Order number sealing ring “material outlet”:

2-liter model: ID 29258

 

5-liter model: ID 23098

8-4 Maintenance

Page 43
Image 43