/Wait until the blower has stopped.

STT40 / STT70

Turn the “Hopper” release switches (ST1, ST2) to the “I” position.

To set the drying temperature, turn the temperature controller to 176° F (+80 °C).

Press the “PGM” key one time.

Set the drying temperature to 176° F using the arrow keys.

After 2 seconds, the display will flash and the value will be stored.

Press the “EXIT” key (the setpoint value and the actual value of the drying temperature are displayed).

After 2 hours, turn the “Hopper” release switches (ST1, ST2) to the “0” position.

Turn the “Timer” switch to the OFF position:

/Wait until the blower has stopped.

The blower will continue running for 10 minutes once it is turned off.

If there is a return air cooler installed, turn off the coolant circuit.

Turn off the dryers’ main power switch.

The “power” signal lamp turns off.

Note: The previous steps only need to be taken if this is the initial startup of the dryer, or if the dryer has been sitting for several months.

Start up 3-3