Sterling STT40, STT70 manual Problem, Possible cause, Corrective action, Process heaters are faulty

Models: STT40 STT70

1 76
Download 76 pages 12.33 Kb
Page 53
Image 53
Process heaters are faulty.

STT40 / STT70

Problem

Possible cause

Corrective action

 

 

 

 

Process heaters are faulty.

Check for open heaters. Replace

 

if required.

 

 

 

Solid-state temperature

Replace.

Loss or reduction of process air

controller faulty.

 

 

Make sure that plant personnel

temperature.

 

Process temperature was

are aware of the proper

 

 

adjusted in error by plant

temperature set point. Post an

 

personnel.

appropriate sign next to the

 

 

controller.

 

Process heaters are faulty.

Replace.

 

Desiccant beds are

Replace desiccant.

 

contaminated.

 

 

 

 

Drying systems are designed for

 

Material being dried differs

the material which was

 

originally specified. Different

 

from material specified at the

 

materials may need a longer

 

time of purchase.

Loss or reduction in drying

residence time or a different

 

 

drying temperature.

capacity.

 

Break in flex hose to/from

Inspect for air leaks; replace as

 

 

drying hopper.

needed.

 

Airflow valve sticking or failing

Check for proper operation of

 

valve actuators. Repair or

 

to shift.

 

replace if necessary.

 

 

 

Blower fins filled with dust or

Remove blower side plate,

 

clean baffles, replace.

 

contaminants.

 

Replace filter elements.

 

 

 

Insufficient power to PLC

Check power supply and power

PLC Regeneration Bed LED

(Power LED is off).

wiring to PLC.

Faulty PLC (PLC Power light is

 

indicators both off.

Replace PLC.

on, Run light is off, and/or Error

 

 

light is on).

 

 

Regenerating bed cooldown.

None.

 

Blower Input indicator is off.

Verify that blower contactor is

 

on. Check input wiring to PLC.

 

 

PLC Regeneration Heater

Process air in high-temperature

None.

condition.

Left/Right output indicators both

 

Insufficient power to PLC

Check power supply and power

off.

(Power light is off).

wiring to PLC.

 

 

Faulty PLC (PLC Power light is

Replace PLC.

 

on, Run light is off, and/or Error

 

light is on).

 

Troubleshooting 9-2

Page 53
Image 53
Sterling STT40, STT70 manual Problem, Possible cause, Corrective action, Process heaters are faulty