6-2 Sun Datacenter Switch 3456 Service Manual • August 2008
6.2 Troubleshooting Fabric Cards
The status LEDs on the fabric cards can help you determine the problem with the
fabric cards. See TABLE6-1.
Additionally,the following commands can provide basic status information:
showpresent
checkpwrfault
checkvoltages
checkswitches
showtemps
Morecomplex and verbosecommands are available for troubleshooting. See the Sun
Datacenter Switch 3456 Administration Guide and Sun Datacenter Switch 3456 Reference
Manual for further information.
TABLE6-1 Fabric Card Status LEDs
Glyph Name Color State and Meaning
Locator White On – No function.
Off– Normal operation.
Flashing – The fabric card is identifying itself.
Ready-to-Remove Blue On – Fabric card has been disabledand is readyto be removed.
Off– Do notremove
Flashing – No function.
Attention Amber On – Fault detected.
Off– No faultdetected.
Flashing – Critical error.
Ok Green On– Normaloperation at full power.
Off– Standby voltage, or no power at all applied.
Flashing – No Function.