FIGURE 2-12Cable Plate Locations

Note – The support rib for the plate is on the underside and visible from the front of the switch chassis. From the back of the switch, the plates appear smooth.

b. Tighten the screws securely.

c.Repeat from Step a for the next higher cable plate and continue until all six cable plates are installed.

2.Repeat Step 1 for the left side of the switch.

Removing Cable Trees

Note – Two people are required to remove the cable trees. One person must hold the weight of the tree for an extended time.

1.Remove all cables from the line cards.

See “Removing Cables From the Sun Datacenter Switch 3456” on page 2-22.