iPort/AFM Connection Closed

Prompt: /I88[CR]

‘iPort/AFM Connection is Closed.

Cause: Host is attempting to perform an I2C Bus message operation while the iPort/AFM Connection is Closed. The Host should issue an Open I2C Connection command before attempting to perform I2C Bus message operations.

Invalid Command Argument

Prompt: /I89[CR]

‘Invalid Command Argument Detected

Cause: This event normally indicates the value of a Host command argument was out of range. The Host should reissue command with correct arguments.

Slave Transmit Request Not Active

Prompt: /I8A[CR]

‘Slave Transmit Request Not Active

Cause: This event indicates the Host attempted to issue a Slave Transmit Text command when no Slave Transmit Request was present.

Invalid iPort/AFM Command

Prompt: /I8F[CR]

‘Invalid iPort/AFM Command

Cause: This event normally indicates that an invalid command was issued by the Host. The Host should reissue the correct command.

iPort/AFM RS-232 Receive Buffer Overflow

Prompt: /I90[CR]

‘iPort/AFM RS-232 Receive Buffer Overflow

Cause: This event normally indicates that data sent to the iPort/AFM via the RS-232 serial port has been lost. Check your Host Computer Serial Port Flow Control (XON/XOFF, or Hardware) to make sure it matches current iPort/AFM Flow Control. Also check if Host Computer FIFO buffers in the 16550 UART are enabled. If so, reduce Transmit Buffer level.