ElseIf (StrComp(iPortResp$, "/BC2") = 0) Then

' iPort/AFM Baud Change 2 {115.2K}

TextBox.Text = "iPort/AFM Baud Change 0 {115.2K} "

' Test for iPort/AFM Asynchronous Interface Events

ElseIf (StrComp(iPortResp$, "/SRC") = 0) Then

' Slave Rx Complete Processing

 

TextBox.Text = LineBuf$

'Update Display

ElseIf (StrComp(iPortResp$, "/GRC") = 0) Then ' General Call Rx Complete Processing

TextBox.Text = LineBuf$

'Update Display

ElseIf (StrComp(iPortResp$, "/STR") = 0) Then

' Slave Tx Request Processing

 

Comm1.Output = "/S~00~01"

'Send Slave Tx Msg

Comm1.Output = Chr$(13)

'Terminate Command

TextBox.Text = LineBuf$

'Update Display

ElseIf (StrComp(iPortResp$, "/NSA") = 0) Then

' iNterrupt Signal Assert Detected

TextBox.Text = iNterrupt Signal Assert Detected

'Update Display

ElseIf (StrComp(iPortResp$, "/NSR") = 0) Then

' iNterrupt Signal Release Detected

TextBox.Text = iNterrupt Signal Release Detected

'Update Display

' Test for iPort/AFM Response Messages

ElseIf (StrComp(iPortResp$, "****") = 0) Then TextBox.Text = "* iPort/AFM Ready" 'Update Display

ElseIf (StrComp(iPortResp$, "/SNA") = 0) Then TextBox.Text = "/SNA Slave Not Acknowledging"

ElseIf (StrComp(iPortResp$, "/I81") = 0) Then TextBox.Text = "/I81 iPort/AFM Busy" 'Update Display

ElseIf (StrComp(iPortResp$, "/I83") = 0) Then