Monitoring Statistics 7-13
3. Refer to the Total AP RF Traffic field to view throughput information for the AP-5131 and 
WLAN.
4. Click the Clear RF Stats button to reset each of the data collection counters to zero in order 
to begin new data collections.
5. Click the Logout button to securely exit the AP-5131 Symbol Access Point applet. A prompt 
displays confirming the logout before the applet is closed.
7.3.1 Viewing WLAN StatisticsUse the WLAN Stats screen to view detailed statistics for individual WLANs.The WLAN Stats 
screen is separated into four fields; Information, Traffic, RF Status, and Errors. The Information field 
displays basic information such as number of associated Mobile Units, ESSID and security 
Retries Displays the average number of retries per packet. An excessive 
number could indicate possible network or hardware problems.
Clear All WLAN Stats Click this button to reset each of the data collection counters to 
zero in order to begin new data collections.
Do not clear the WLAN stats if currently in an important data 
gathering activity or risk losing all data calculations to that point.
Total pkts per second Displays the average number of RF packets sent per second across 
all active WLANs on the AP-5131. The number in black represents 
packets for the last 30 seconds and the number in blue represents 
total pkts per second for the last hour.
Total bits per second Displays the average bits sent per second across all active WLANs 
on the AP.-5131 The number in black displays this statistic for the 
last 30 seconds and the number in blue displays this statistic for 
the last hour.
Total associated MUs Displays the current number of MUs associated with the active 
WLANs on the AP-5131. If the number is excessive, reduce the 
maximum number of MUs that can associate with the AP-5131, for 
more information, see Creating/Editing Individual WLANs on page 
5-24.
Clear all RF Stats Click the Clear all RF Stats button to reset statistic counters for 
each WLAN, and the Total AP RF totals to 0. Do not clear RF stats 
if currently in an important data gathering activity or risk losing all 
data calculations to that point.