TANDBERG 6000 MXP Profile

3.13.1.7 Warnings

If any warnings registered by the system it will be displayed in the Warnings menu. Open a warning in the list to get more information about the warning.

The following warnings may be displayed if detected by the system, depending on system type and configuration:

ISDNBRI warnings

ISDN is enabled on BRI line x, but the line is not connected. Please check your network

connection or disable the line. (101)

There is something wrong with ISDN BRI line x. Please check your network connection. (102)

IP networkquality warnings

The system is experiencing packet loss in the IP network. This may affect the quality of

the call.

The system is experiencing high jitter in the IP network. This may affect the quality of the

call.

The system is dropping IP packets due to latency in the network. This may affect the quality of the call.

ISDNPRI warnings

ISDN PRI is configured for this system, but the line is not connected. Please check your

network connection or disable the network. (131)

There is something wrong with the ISDN PRI line (Blue alarm). Please check your

network connection. (132)

There is something wrong with the ISDN PRI line (Yellow alarm). Please check your

network connection. (133)

There is something wrong with the ISDN PRI line (D-Channel not active). Please check your network connection. (134)

ExternalNetwork warnings

External Network is configured for this system, but the line is not connected. Please check your network connection or disable the network. (161)

LeasedE1/T1 warnings

Leased E1/T1 is configured for this system, but the line is not connected. Please check

your network connection or disable the network. (191)

There is something wrong with the Leased E1/T1 line (Blue alarm). Please check your network connection. (192)

112

Page 112
Image 112