Administrator Settings

4.8.4Data Port

The system provides up to two standard RS232 serial ports to allow a computer to be connected for data transfer and control purposes. Note that when connecting to a PC the connecting cable must be a straight through RS232 cable.

Baud Rate, Parity, Databits and Stopbits

If you wish to connect a PC to Data port 1, you must ensure that the PC and the system are identically configured. The available settings are:

Baud

Rate

Parity

Databits

Stopbits

1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 None, Odd, Even

7, 8 1, 2

The control interface provided by the data port supports a subset of the Hayes command set as well as acomprehensive set of system specific commands. It maintains communication with the data port s command interpreter at all times. All features available from the hand-held remote control can be accessed through the data port.

Data Port 2

Data port 2 is dedicated to the main camera and will not be available in standard configuration. The Data Port 2 menu contains the same items as the Data Port 1 menu; Baud rate, Parity, Databits, Stopbits except for the Mode, which has VISCA and Auto selections.Mode.

The system will automatically detect WAVE cameras. If you are using a camera supporting the VISCA protocol, select Mode: VISCA.

If Mode is Auto and no camera is connected to the Data port 2, the Baudrate, Parity, Databits and Stopbits settings will be enabled.

217

Page 217
Image 217
TANDBERG 6000MXP user manual Data Port, Baud Rate, Parity, Databits and Stopbits