Serial V.35 Board

Serial V.35 Board Interfaces

TANDBERG MPS ADMINISTRATOR GUIDE

Slot (1 to n)

Select Slot 1 to 6 to configure the Serial V.35 Board(s). The picture shows that Serial V.35 Boards installed on Slot 4.

Indicates ok

Indicates an error

Internal Bandwidth

Sets the clock rate the MPS will provide to all ports when set to Internal for clocking. Can be set to a clock rate from 64kbps up to 1920 kbps.

Call Control, port 1-32

Dial Manual: Select Dial Manual when no handshake signals are available or when using RS366 with other IMUX and the external equipment requires a constantly connected line. (Default: Dial Manual)

RS366 ADTRAN: Select RS366 ADTRAN only when con- nected to an ADTRAN ISU 512.

The ADTRAN ISU 512 offers extra usability when dialling RS366 via an ADTRAN ISU 512 IMUX.

This dialling scheme will map the call type and bandwidth selection to ADTRAN ISU 512 specific suffixes to the dialled number.

Clocking, port 1-32

Dual: When using RS449, RS530, and V.35 the external equipment provides two clock signals, one for transmit and one for receive. The difference between RS449, RS530 and V.35 is the cable only (Default: Dual).

Single: Used when the external equipment provides one com- mon clock signal, X.21, for both transmit and receive.

Network Configuration

Save - Press the Save button to save changes.

DTR Puls, port 1-32

On: Set to On if the port is used for incoming Gateway calls.

Off: Set to Off if the port is not used for incoming Gateway

calls. (Default: Off)

Main

Table of

Introduction

Installation

Contents

 

 

 

D 13373.08

 

 

 

NOVEMBER 2007

 

 

 

Gateway Bandwidth, port 1-32

The incoming connection Bandwidth may be set to:

64 kbps, 128 kbps, 192 kbps, 256 kbps, 320 kbps, 384 kbps, 512 kbps, 768 kbps, 1152 kbps, 1472 kbps, 1536 kbps and 1920 kbps (Default: 384 kbps).

This is for incoming Gateway calls and has no effect when used for MCU calls.

Quick

Using

System

System

Gateway

Setup

the MPS

Status

Configuration

Configuration

100

Restrict, port 1-32

On: When set to On, call rates are increment- ed in steps of 56 kbps.

Off: When set to Off, call rates are increment-

ed in steps of 64 kbps. (Default: Off)

MCU Technical

Configuration Descriptions Appendices

MPS

Page 100
Image 100
TANDBERG MPS 200, MPS 800 manual 100, Serial V.35 Board Interfaces

MPS 800, MPS 200 specifications

The TANDBERG MPS 200 is an advanced multipoint conferencing solution designed to enhance communication and collaboration in various environments. Renowned for its robust performance and versatile features, the MPS 200 caters to businesses and organizations seeking to integrate video conferencing seamlessly into their operations.

One of the standout features of the MPS 200 is its ability to support high-definition video conferencing. Ensuring crystal-clear imagery, it accommodates various video standards, including H.264, allowing for efficient bandwidth usage without compromising quality. This makes it an excellent choice for organizations that require high-quality video for their meetings, presentations, or training sessions.

The MPS 200 also supports a wide range of participants, facilitating large-scale conferences with multiple endpoints. It can connect numerous participants simultaneously, allowing teams from different locations to collaborate effectively. This scalability is essential for businesses that frequently host meetings with various stakeholders, enabling seamless interaction and engagement.

Another noteworthy technology integrated into the MPS 200 is its flexibility in connectivity. It supports a variety of protocols, including SIP and H.323, ensuring compatibility with existing infrastructure. This flexible design allows organizations to integrate the MPS 200 into their current systems with minimal disruptions, making it an attractive option for businesses looking to upgrade their conferencing capabilities.

In addition to video conferencing, the MPS 200 offers features such as content sharing, which enables users to share documents, presentations, and other materials during meetings. This functionality enhances collaboration by allowing participants to view and discuss content in real-time, fostering engagement and ensuring that everyone remains on the same page.

The user interface of the MPS 200 is designed for ease of use, providing intuitive controls that facilitate quick setup and management of conferences. Users can initiate or join meetings with just a few clicks, ensuring that technology does not hinder productivity.

Security is a priority with the MPS 200, which incorporates various encryption methods to protect sensitive information during video calls. With security becoming increasingly important in today’s digital landscape, this feature offers peace of mind to users, particularly in enterprise environments.

In summary, the TANDBERG MPS 200 stands out as a comprehensive multipoint conferencing solution that delivers high-quality video, extensive connectivity options, and advanced collaboration features. Its user-friendly design, scalability, and robust security measures make it a vital asset for organizations aiming to enhance their communication strategies in the digital age. Whether for internal meetings or external engagements, the MPS 200 serves as an indispensable tool for effective collaboration.