Initial Configuration

System Controller Board - Parameter Configuration

TANDBERG MPS ADMINISTRATOR GUIDE

Initial Configuration

Parameter Configuration

LCD

Before using the TANDBERG MPS it requires some basic configuration. This is done through the Liquid Crystal Display (LCD) on the front of the chassis.

Preparing the MPS

Follow the instructions in the Start-

!ing the System section to prepare the system for configuration.

Press any key to open the main menu.

Use Arrow buttons to select from the sub- menu and press the Confirm button.

Parameter Config

Parameter Info

LCD Settings

Restart

Use Arrow buttons to select SC IP Config and press the Confirm button.

SC IP Config

Media IP Config

Use Arrow buttons to select a line and set the three addresses and the Ethernet speed. Use Arrow Left to step back in the menu.

IP <192.168.001.100>

SNM <255.255.255.000>

GW <192.168.001.001>

IF Speed <100Full>

Static Network Addresses

Follow the instructions, to the right, to con- figure static network addresses and Ethernet speed of the System Controller Board (SC) and the Media Processing Board.

Access to the MPS

After configuring the IP-address of the System Controller Board (and restart the MPS), you may continue the configuration from the web interface. You have access to the TANDBERG MPS by entering the IP-address of the System Controller Board in a standard Web-browser.

Parameter Config - Configuration of System

SC IP Config - Configuration of the System

IP: Defines the static IP address of the System

Controller Board(s) and Media Processing

Controller Board.

Controller Board: Example <192.168.001.100>

Board(s).

 

SNM: Defines the static IP Subnet Mask for

Parameter Info - See the configuration of

 

 

the network: Example <255.255.255.000>

the System Controller Board(s) and Media

 

GW: Defines the static IP Gateway address:

Processing Board(s).

 

 

Example <192.168.001.001>

LCD Settings - Configuration of the LCD.

 

 

IF Speed: Defines the Ethernet speed: <Auto/

Restart - Restart the MPS

 

 

10Half/10Full/100Half/100Full>

Enter Password

You will be asked to enter a password. The Internet Explorer 7 requires a User Name to be entered. Could be such as ‘admin’. The default password for the TANDBERG MPS is “TANDBERG”. The password is case sensitive.

Change Password

To change the password of the system, you need to log into the Command Line Interface. For information please see the TANDBERG MPS API document supplied with the system or on www.tandberg.com.

LCD buttons

Press Arrow Up to move up in the menu or to increase a digit (0 –> 9)

Press Arrow Down to move down in the menu or to decrease a digit (9 –> 0)

Press Arrow Left to step back in the menu or to move the next digit to the left

Press Arrow Right to step forward in the menu or to move the next digit to the right

Press Confirm button to confirm a selection

Restart the TANDBERG MPS

To activate changes to the Parameter Configuration the MPS requires a restart.

Use Arrow Left to step back to the main menu and select Restart

Main

Table of

Introduction

Contents

 

 

D 13373.08

 

 

NOVEMBER 2007

 

 

Installation

Quick

Using

System

System

Gateway

MCU

Technical

Appendices

Setup

the MPS

Status

Configuration

Configuration

Configuration

Descriptions

 

 

 

 

28

 

 

 

 

 

MPS

Page 28
Image 28
TANDBERG MPS 200, MPS 800 manual System Controller Board Parameter Configuration, Initial Configuration

MPS 800, MPS 200 specifications

The TANDBERG MPS 200 is an advanced multipoint conferencing solution designed to enhance communication and collaboration in various environments. Renowned for its robust performance and versatile features, the MPS 200 caters to businesses and organizations seeking to integrate video conferencing seamlessly into their operations.

One of the standout features of the MPS 200 is its ability to support high-definition video conferencing. Ensuring crystal-clear imagery, it accommodates various video standards, including H.264, allowing for efficient bandwidth usage without compromising quality. This makes it an excellent choice for organizations that require high-quality video for their meetings, presentations, or training sessions.

The MPS 200 also supports a wide range of participants, facilitating large-scale conferences with multiple endpoints. It can connect numerous participants simultaneously, allowing teams from different locations to collaborate effectively. This scalability is essential for businesses that frequently host meetings with various stakeholders, enabling seamless interaction and engagement.

Another noteworthy technology integrated into the MPS 200 is its flexibility in connectivity. It supports a variety of protocols, including SIP and H.323, ensuring compatibility with existing infrastructure. This flexible design allows organizations to integrate the MPS 200 into their current systems with minimal disruptions, making it an attractive option for businesses looking to upgrade their conferencing capabilities.

In addition to video conferencing, the MPS 200 offers features such as content sharing, which enables users to share documents, presentations, and other materials during meetings. This functionality enhances collaboration by allowing participants to view and discuss content in real-time, fostering engagement and ensuring that everyone remains on the same page.

The user interface of the MPS 200 is designed for ease of use, providing intuitive controls that facilitate quick setup and management of conferences. Users can initiate or join meetings with just a few clicks, ensuring that technology does not hinder productivity.

Security is a priority with the MPS 200, which incorporates various encryption methods to protect sensitive information during video calls. With security becoming increasingly important in today’s digital landscape, this feature offers peace of mind to users, particularly in enterprise environments.

In summary, the TANDBERG MPS 200 stands out as a comprehensive multipoint conferencing solution that delivers high-quality video, extensive connectivity options, and advanced collaboration features. Its user-friendly design, scalability, and robust security measures make it a vital asset for organizations aiming to enhance their communication strategies in the digital age. Whether for internal meetings or external engagements, the MPS 200 serves as an indispensable tool for effective collaboration.