Turbomachinery Package SpecificationTaurus 60 Compressor Set and Mechanical Drive
Variable Frequency Drive (cont.)
Power Factor |
| 0.96 | |
Efficiency |
| 98% | |
Minimum/Maximum Operating Temperature | |||
Heat Rejection |
|
| |
- 380 to 460 VAC Input | 1780 watts | ||
Input Fuse Rating |
| 225 amp | |
Approximate Measurements |
| ||
- Height |
| 85 cm (33.5 in.) | |
- Width |
| 42 cm (16.6 in.) | |
- Depth |
| 32 cm (12.7 in.) | |
Approximate Weight | 70 kg (155 lb) | ||
Starter Motor |
|
| |
Motor Type |
| ||
Motor Voltage Rating | 380 AC, (0 to 133 Hz) | ||
Power |
| 56 kW (75 hp) | |
Operating Speed |
| 0 to 4000 rpm | |
Maximum Breakaway Amperage | 205 amps | ||
Maximum Breakaway Torque | 472 | ||
Minimum/Maximum Operating Temperature | |||
Space Heater Voltage | 120 VAC, 60 Hz | ||
|
|
| 240 VAC, 50 Hz |
Approximate Measurements |
| ||
- Length |
| 75 cm (29.4 in.) | |
- Diameter |
| 45.7 cm (18 in.) | |
Approximate Weight |
| ||
- AC Starter Motor Assembly | 370 kg (820 lb) | ||
Power Wiring |
|
| |
VFD to Starter Motors Power Cable Length | 38 m (123 ft), See Note (b) | ||
Solar’s Applicable Engineering Specifications |
| ||
ES 1593 |
| Guidelines for NEC Compliance of Solar Product Lines: Class I, Group D, Division 1 and | |
|
| Division 2 |
|
ES 1762 |
| Standards and Practices for Electrical Systems For Gas Turbine Packages Installed in | |
|
| Hazardous Areas (CENELEC Standards) | |
Solar’s Applicable Product Information Letters |
| ||
PIL 149 |
|
| |
Notes: |
|
|
(a)Feeder circuits exceeding this limit require the use of an isolation transformer, line reactor, or other means of adding similar impedance to limit fault current.
(b)Longer cable runs may require an onskid marshalling box and/or output line reactor.
© 2009 Solar Turbines Incorporated. All rights reserved. | TPS60CSMD/309 |