Turbomachinery Package Specification | Taurus 60 Compressor Set and Mechanical Drive |
|
|
7.3Pneumatic Start System (Optional)
The pneumatic start system, (Figure 11) can use either process gas or compressed air as a power source. The standard system consists of a strainer, shutoff valve, pneumatic starter motor, and associated stainless steel piping and manifolds. The pneumatic starter motor is mounted directly on the gas turbine accessory drive gearbox and transmits starting power to the gas turbine via an overrunning clutch and shaft. When the gas turbine reaches starter dropout speed, the start system is
Pneumatic Start Motor
Fluid | Air or Natural Gas See Note (a) |
Pressure | 1379 to 2758 kPag (200 to 400 psig) |
Flow | 113 nm3/min (4000 SCFM) |
1 Minute Exhaust Purge Consumption | 119 nm3 (4200 SCF) |
Solar’s Applicable Engineering Specifications |
|
ES 2201 | Auxiliary Service Air |
Notes:
(a)The particle size in the air stream should not exceed 10μ. Since it is impractical to remove 100% of all particles larger than 10μ, this is defined as ß10 > 100, or 99% efficient. Oil or hydrocarbon content should not exceed 1 ppm. The dew point at line pressure shall be at
least 6°C (10°F) below the minimum temperature to which any part of the air system is exposed or between
© 2009 Solar Turbines Incorporated. All rights reserved. | TPS60CSMD/309 |