Turbomachinery Package Specification | Taurus 60 Compressor Set and Mechanical Drive |
|
|
Construction Materials
Prefilter/Barrier |
| Carbon Steel (Standard); 316L Stainless Steel |
|
| (Optional) |
Insect Screen (Optional) | 316L Stainless Steel | |
Self Cleaning Barriers | Carbon Steel (Standard); 316L Stainless Steel | |
|
| (Optional) |
Marine High Velocity Air Cleaner | 316L Stainless Steel | |
Offshore / Coastal Medium Velocity Type Air | 316L Stainless Steel (Standard), Carbon Steel | |
Filter |
| (Optional for mild coastal environments) |
Air Inlet Silencer |
| Carbon Steel (Standard); 316L Stainless Steel |
|
| (Optional) |
Air Inlet Support Structure | Carbon Steel (Standard) | |
Solar’s Applicable Product Information Letters |
| |
PIL 054 | OSHA Noise Requirements |
|
PIL 178 | Salt Ingress Protection for Gas Turbines | |
Notes: |
|
|
(a)The particle size in the compressed air stream should not exceed 10μm. Since it is impractical to remove 100% of all particles larger than 10μm, this is defined as ß10 > 100, or 99% efficient. Oil or hydrocarbon content should not exceed 1 ppm. The dew point at line pressure shall be at least 6°C (10°F) below the minimum temperature to which any part of the air system is exposed or between 1.6°C and 60°C (35°F and 140°F). Air should be free of all corrosive contaminants, hazardous gases, flammables, and toxics.
© 2009 Solar Turbines Incorporated. All rights reserved. | TPS60CSMD/309 |
59