Turbomachinery Package Specification

Taurus 60 Compressor Set and Mechanical Drive

 

 

15 Accessory Equipment

15.1Battery Charger System

The battery charger system consists of a battery charger (Figure 27) and batteries to provide 120 VDC emergency power to the control console, fuel valve, bleed valve and variable guide vane actuators, and the DC backup lube oil pump. The control console 120 to 24 volt DC-to-DC converter provides 24 VDC power for the control system. The battery charger system is designed for indoor installation in a nonhazardous area. Battery options include:

Valve Regulated Lead Acid

Nickel Cadmium

15.1.1Valve Regulated Lead Acid

The batteries are mounted on a freestanding two-tier, two-row rack. The batteries are shipped fully charged and ready for use.

15.1.2Nickel Cadmium

The batteries are mounted on a freestanding, four-step rack. The batteries are shipped wet, fully charged, and ready for use.

Figure 27. Typical Battery Charger

15.2Turbine Cleaning System

The optional turbine compressor cleaning system (Figure 28) facilitates periodic cleaning of the turbine compressor. The cleaning system is designed for use in salt-laden or dusty environments or where compressor contamination from hydrocarbon vapors is possible. The turbine compressor cleaning system is composed of the following systems:

On-crank cleaning system

On-line cleaning system

Both cleaning systems are independent of each other and include a separate distribution manifold with pressure atomizing spray nozzles in the engine air inlet collector, onskid piping, strainer, and solenoid shutoff valves to deliver water or approved cleaning fluid to the manifold. Both systems require an external source of clean-filtered air to pressurize the cleaning solutions.

© 2009 Solar Turbines Incorporated. All rights reserved.

TPS60CSMD/309