Turbomachinery Package Specification | Taurus 60 Compressor Set and Mechanical Drive |
|
|
Enclosure
Optional Ventilation Fan Motor Voltage Ratings | 380 VAC, 400 VAC, and 415 VAC (50 Hz) |
| 460 VAC and 575 VAC (60 Hz) |
Primary Enclosure Lighting Voltage | 220 VAC (50 Hz) or 110 VAC (60 Hz) |
Standby Enclosure Lighting Voltage | 120 VDC |
Sound Pressure Level | See Note (a) |
Enclosure Roof Load | 244 kg/m2 (50 lb/ft2) |
Enclosure Wind Load | 193 kph (120 mph) |
Approximate Measurements |
|
Height | 2.6 m (8 ft 6 in.), Does Not Include Ventilation Ducting |
Width | 6.4 m (21 ft), With Enclosure Doors Open and Engine |
| Removal Hoist Attached |
Driver Length | 6.1 m (20 ft) |
Driven Length (Single Body Compressor) | 4 m (13 ft) |
Approximate Weights |
|
Gas Turbine Enclosure | 3054 kg (6750 lb) |
Compressor Enclosure (Single Body) | 1656 kg (3660 lb) |
Fire Suppression System Compliance |
|
CO2 Fire Suppression System | U.S. National Fire Protection Association (NFPA) 12 |
| United States Coast Guard (USCG) CFR 46 |
Water Mist Fire Suppression System | U.S. NFPA Code 750 |
| USCG CFR 46 |
Water Mist Fire Suppression System |
|
Minimum Operating Temperature | 4°C (40°F), Optional Heater Available |
CO2 Fire Cylinder Cabinets |
|
Fire Cylinder Cabinet, Main |
|
Height | 213 cm (84 in.) |
Width | 152 cm (60 in.) |
Depth | 53 cm (21 in.) |
Approximate Cabinet Weight | 429 kg (946 lb), Without Cylinders |
Approximate Cylinder Weight | 45 kg (100 lb) |
© 2009 Solar Turbines Incorporated. All rights reserved. | TPS60CSMD/309 |