Turbomachinery Package SpecificationTaurus 60 Compressor Set and Mechanical Drive
Solar’s Applicable Engineering Specifications
ES | Fuel, Air, and Water (or Steam) for Solar Gas Turbine Engines |
ES 1593 | Guidelines for NEC Compliance of Solar Product Lines: Class I, Group D, Division 1 |
| and Division 2 |
ES 1762 | Standards and Practices for Electrical Systems for Gas Turbine Packages Installed In |
| Hazardous Areas (CENELEC/IEC Standards – European ATEX Directive 94/9/EC) |
Solar’s Applicable Product Information Letters | |
PIL 058 | Package Sound Levels |
PIL 161 | Lube Oil System Cleanliness |
Notes:
(a)A pressure control valve regulates main lube oil supply pressure to
(b)Prevailing winds must be considered to prevent the lube oil cooler from exhausting into the engine air inlet system or to take air in from the engine exhaust system. No airflow backpressure is allowed at the lube oil cooler face.
(c)The maximum total design pressure drop of the off skid oil cooler loop including supply and return lines shall not exceed 276 Kpad (40 psid) at the design flow rate and an oil viscosity of 60 ssu (10.5 centistokes). No check valves are allowed in the oil cooler loop. This is recommended for all applications (but mandatory for units in cold climates), oil cooler supply, return and optional vent lines must slope from the oil cooler to the turbine package to facilitate draining when the unit is not operating.
(d)The heater is mandatory if unit ambient temperature is less than 10°C (50°F).
(e)The lube oil tank immersion heater ensures the lube oil tank temperature remains above 10°C (50°F) for starting in cold temperatures.
(f)The flame arrestor must be installed vertically at the end of the lube tank vent piping.
(g)
(h)An additional 246 L (65 gal) is required for package filters and piping. Additional oil will also be required to fill any offskid oil piping and vessels (if applicable).
© 2009 Solar Turbines Incorporated. All rights reserved. | TPS60CSMD/309 |