Turbomachinery Package Specification

Taurus 60 Compressor Set and Mechanical Drive

 

 

Offskid Control Console Dimensions

One-Bay Control Console

 

Height

 

2286 mm (90 in.)

Width

 

914 mm (36 in.)

Depth

 

800 mm (32 in.)

Approximate Weight

570 kg (1250 lb)

Two-Bay Control Console

 

Height

 

2286 mm (90 in.)

Width

 

1448 mm (57 in.)

Depth

 

800 mm (32 in.)

Approximate Weight

680 kg (1500 lb)

Supervisory Interface Modules

 

ControlNet 1.5

 

 

Cables

 

RG-6U Coaxial

Maximum Cable Length

1000 m (3300 ft)

Transmission Protocol

Common Industrial Protocol (CIP)

Transmission Speed

5 Mbps

Ethernet

 

 

Cables

 

10BaseT

Network Length

 

100 m (330 ft) To Nearest Hub

Transmission Protocol

CIP Protocol with TCP/IP

Transmission Speed

10 Mbps

Data Highway Plus

 

 

Cables

 

DH+ Twisted Pair

Maximum Cable Length

3000 m (10,000 ft)

Transmission Protocol

CIP or DF1 Protocol

Transmission Speed

57.6 bps

Modbus

 

 

Cables

 

RS232C, RS422, or RS485

Cable Length

 

RS232C: 15 m (50 ft)

 

 

 

RS422 and RS485: 1200 m (4000 ft)

Transmission Protocol

Subset of Modbus RTU Protocol

Package End Devices

 

Transmitters

 

4-20 mA

Switches

 

0-24VDC

Thermocouples

 

Type K

RTDs

 

100 ohm Platinum

Proximitors

 

3300XL

Solar’s Applicable Engineering Specifications

 

ES 9-56

 

Fusion Welding

 

ES 1593

 

Guidelines for NEC Compliance of Solar Product Lines: Class I, Group D, Division 1

 

 

and Division 2

 

ES 1762

 

Standards and Practices for Electrical Systems for Gas Turbine Packages Installed In

 

 

Hazardous Areas (CENELEC/IEC Standards – European ATEX Directive 94/9/EC)

ES 2231

 

Standards and Practices for The Design and Installation of Cable Channels and TC

 

 

Rated Cables Installed In Class 1, Division 2 Hazardous Areas

© 2009 Solar Turbines Incorporated. All rights reserved.

TPS60CSMD/309

43