14 Model H63Important: Tothe Operator
Following are the variable messages which will appear
on line 3:
1. PO WER SWITCH OFF: Power switch was in
the OFF position.
2. MIX OUT PRESENT: There was a mix out
condition present.
3. AUTO O RSTANDBY OFF: Theunit was not in
the AUTO or STANDBY mode.
4. NO HEAT CYCLE TRIED: A heat tr eatment
cycle was not attempted in the last 24 hours.
(AUTO HEAT TIME was advanced, or a power
loss was experienced at the time the cyclewas
to occur, or a heat cycle failure not due to a
thermistor failure.)
If the following screen appears, a soft lock has
occurred during the heat treatment cycle.
HEATTREAT CYCLE
FAILURE
FREEZER LOCKED
PRESS SEL KEY
If the temperature of the product has not fallen below
41_F(5_C) by the end of the COOL cycle, the following
screen will appear.
PRODUCT OVER TEMP
FREEZER LOCKED
PRESS SEL KEY
Press the MENU/SEL key to advance to the next
display.
When one of these messages appears, automatic
freezer operation cannot take place until t he freezer is
disassembled and brush cleaned or has completed a
heat treatment cycle.
Thenext display will inst ruct the operator to start a heat
treatment cycle manually (by pressing the AUTO key),
or to disassemble and brush clean the freezer. If the
AUTO key is pressed, the freez er will automatically
start the heat treatment cycle and only the heat cycle
LED will light.
NO AUTO OPERATION
ALLOWED. PRESS
AUTO FOR HEATCYCLE
WASHTO BRUSH CLEAN
If the WASH key is pressed, the next display will
appear and the freezer will have to be disassembled
and brush cleaned.
MODE: OFF
MIX: OK
HOPPER TEMP: 41.0F
FREEZER LOCKED
Once the freezer is unlocked by starting a heat
treatment cycle, only the heat cycle LED will light. If t he
freezer is unlocked by brush cleaning, the mix low and
mix out LED’s will light.
Operator Menu
The OPERATOR MENU is used to enter the operator
function displays.To access the OPERATOR MENU,
simply press the MENU/SEL key. The cursor willflash
over the letter “A” indicating that this is screen “A”. To
select a different screen, use the arrow keys and move
the cursor to the desired screen selection and press
the MENU/SEL key.
OPERATORMENU
ABCDEFGHIJK
EXIT FROM MENU
<------ ------> SEL
Screen “B” is FAULT DESCRIPTION. The fault
description will indicate if there is a fault wit h the
freezer.
FAULTDESCRIPTION
VARIABLEMESSAGE
CLR SEL