5
Model H63 Safety
111114
Section 3 Safety
Weat Taylor Company are concerned about t he safety
of the operator when he or she comes in contact with
the freezer and its parts. Taylor has gone to extreme
efforts to design and manufacture built --in safety
features to protect both you and the service technician.
As an example, warning labels have been attached to
thef reezer to further point out safety precautions to t he
operator.
IMPORTANT -- Failure to adhere to the
following safety precaut ions may result in severe
personal injury or death. Failure to comply with
these warnings may damage the machi ne and its
components. Component damage will result in
part replacement expense and service repair
expense.
DO NOT operate the freezer without reading
this Operator Manual. Failure to follow this instruction
may result in equipment damage, poor freezer
performance, health hazards, or personal injury.
Per IEC 60335--1 and its part 2 standards, “This
appliance is to be used only by trained personnel. It is
not intended for use by children or people with reduced
physical, sensory, or mental capabilities, or lack of
experience and knowledge, unless given supervision
or instruction concerning the use of the applianc e by
a person responsible for their safety.”
This unit is provided with an equipotential
grounding lug that is to be properly attached to the rear
oft he frame by the authorized installer. The ins tallation
location is marked by the equipotential bonding
symbol (5021 of IEC 60417-1) on both the removable
panel and the equipment’s frame.
DO NOT use a water jet to clean or r inse the
freezer. Failure to follow these instructions mayresult
in serious electrical shock.
SDO NOT operate the freezer unless it is
properly grounded.
SDO NOT operate the freezer with larger
fuses than specified on the freezer data
label.
SDO NOT attempt any repairs unless the
main power supply to the freezer has been
disconnected. Contact your local authorized
Taylor Distributor for service.
SStationary appliances which are not
equipped with a power cord and a plug or
another device to disconnect the appliance
from the power source must have an all-pole
disconnecting device with a contact gap of
at least 3mm installed in the external
installation.
SAppliances that are permanently connected
to fixed wiring and for which leakage
currents may exceed 10 mA, particularly
when disconnected, not used for long
periods, or during initial installation, shall
have protective devices such as a GFI to
protect against the leakage of current,
installed by authorized personnel to the local
codes.
SSupply cords used with this unit shall be
oil-resistant, sheathed flexible cable, not
lighter than ordinary polychloroprene or
other equivalent synthetic
elastomer-sheathed cord (Code designation
60245 IEC 57) installed with the proper cord
anchorage to relieve conductors from strain,
including twisting, at the terminals and
protect the insulation of the conductors from
abrasion.
Failure to follow these instructions may result in
electrocution. Contact your local aut horized Taylor
Distributor for service.