15
Model H63 Important: To the Operator
060807
Clearing Fault Tones
To clear the tone for any faults which have been
corrected, press the <-- --arr ow key.To see if there is
more than one fault, press the MENU/SEL key.When
the last fault is displayed, the cont rol will return to the
OPERATOR MENU. To return to the main screen,
move the cursor to “A” and press the MENU/ SEL key
again.
Listed below are the variable messages which will
appear, along with the corrective action:
1. NO FAULT FOUND: There was no fault found
in the freezer. Nothing will appear on the screen
after this variable message appears.
2. BE ATEROVERLO AD: Press the reset button
firmly. Clear the tone per instructions in
“Clearing Fault Tones” on page 15.
3. CHK RE FRIG SYS PSI: Place the power
switch in the OFF position. Wait 5 minutes for
the machine to cool. Place the power switch in
the ON position. Clear the tone per instructions
in “Clearing Fault Tones” on page 15.
4. CO MP ON TOO LONG: Place the power
switch in the OFF position. Call service
technician. Clear the tone per instructions in
“Clearing Fault Tones” on page 15.
5. HOPPER THERM BAD: Place the power
switch in the OFF position. Call service
technician.
6. BARRE L THERM BAD: Place the power
switch in the OFF position. Call service
technician.
7. GLYCOL THERM BAD: Place the power
switch in the OFF position. Call service
technician.
8. HOPPER O VER TEMP: The hopper
temperature has risen too high as follows. Clear
the tone per instructions in “Clearing Fault
Tones” on page 15.
a. T he hopper temperature reaches 41_F.
(5_C.) or higher after a power failure.
b. T he hopper temperature has not fallen below
41_F. (5 _C.)by the end of t he COOL phase
in the heat cycle.
9. BA RREL OVER TEMP: The barrel temperature
has risen too high as follows. Clear the tone per
instructions in “Clearing Fault Tones” on
page 15.
a. T he barrel temperature reaches 41_F. ( 5_C.)
or higher after a power failure.
b. T he barrel temperature has not fallen below
41_F. (5 _C.)by the end of t he COOL phase
in the heat cycle.
10. PO WER FAILURE: This message will appear
in the FAULT DESCRIPTION if a power failure
has occurred. Clear the tone per instructions in
“Clearing Fault Tones” on page 15.
Screen “C” is SET CLOCK. This screen will display the
current date and time. The date and time may onlybe
changed after the freezer has been manually brush
cleaned but before it has been placed in the AUTO
mode. Move the cursor under the number you wishto
change. Press the plus key to increase the number;
press the minus key to decrease the number. When
the desired time and date appears, press the
MENU/SEL key once to return t o the OPERATOR
MENU.
SET CLOCK
10:21 AM 5/07/2002
-- --
<------ ------> +++ ------ SEL
If an invalid date is entered, the following screen will
appear.
SET CLOCK
10:34 AM 02/30/2002
-- -- IN VA L I D D AT E
<------ ------> +++ ------ SEL
When the MENU/SEL key is pressed, the controller
will return to the previous LCD screen to allow f or
correction of the calendar entry. The controller will not
advance to the next screen until a valid date has been
entered. Once a valid date has been entered, pressing
the MENU/SEL key will display a the Daylight Saving
Time screen.
DAYLIGHTSAVING TIME
ENABLE DISABLE
_____
<--------> SEL