17
Model H63 Important: To the Operator
Screen “G” is HEAT CYCLE DATA. The information
from the previous heat treatment cycles can be
obtained through this screen. The most recent heat
treatment cycle data will be shown first; press the plus
keyto scroll through the remaining heat cycle displays.
If a heat treatment cycle failure should occur, a two
character message will appear on the second line of
the screen. Press the MENU/SEL key once to return
to the OPERATORMENU.
00:00 00:00 00:00
HEAT OVER COOL RC
00:00 00:00 00:00
TEMP ATEND 0.0 1
Listed below are the variable messages which could
appear:
HT Failure in the heating phase.
CL Failure in the c ooling phase.
TT Failure in meeting total heat treatment cycle
time requirement.
MO Mix out condition.
OP Operator interruption.
PF Power failure. (I f apower failur eocc urs, but
the heat treatment cycle does not fail, an
asterisk (*) will appear on the 3rd line of the
display.)
BO Beater overload.
HO High pressure cut--out.
TH Failed thermistor probe.
PS Power switch placed in the OF F position.
ML Mix Low Condition.
14 14 Day Timeout Occurred.
RC Heat Cycle Record Cleared.
Pressing the <-- -- arrow key on any HEAT CYCLE
DATA screen will cause the extended data screen to
be displayed. This screen shows the hopper, barrel,
and glycol temperatures, and the amount of time t he
freezer spent in the phase of the heat cycle when the
heat cycle completed, or was terminated.
HOPPER BARREL GLYCOL
151.0 134.5 178.0
PHASE TIME: 1:20 1
Screen “H” is the LOCKOUT HISTORY. This screen
displays a history of the last 40 hardlocks, soft locks,
and brush clean dates. Page numbers are indicated in
the upper right hand corner. Page 1 always contains
the most recent failure. Press the +++ key to cycle
through the pages.
The second line of the screen displays the date and
time a failure occurs. The third line indicat es the
reason for a failure, or will indicate a success ful brush
cleaning has occurred. Some failures occur for
multiple reasons. When this occurs, a page will be
generated for each reason. Press the MENU/SELkey
once to return to the Operator Menu.
LOCKOUT HISTORY 1
5/21/02 02:08
SOFTLOCK ABORT
+ + + -- -- -- S E L
Screen “I” is the SERVICE MENU. This screen can
only be accessed by a service technician.
Screen “J” is the STANDBY MODE. To place the
freezer in the STANDBY mode, move the cursor under
the word “yes”. Press the MENU/SEL key to execute
the command. Pressing the MENU/SEL key againwill
return you to the main screen. To exit the STANDBY
mode and place the unit in AUTO, press the AUTO key
once. Pressing the AUTO key again will place the unit
in the OFF mode.
STANDBYMODE
STANDBY YES NO
-- -- --
<------ ------> SEL