SYNC OUT terminal of the DA-88 to the WCK IN terminal of the WR-DA7. Then press the D-I/O switch of the WR-DA7 several times in order to display the INPUT SET screen of the D-I/O window. Then, select the SOURCE SELECT to ‘WCK IN.’

When the DA-98 or 38 is the wordclock master, the slot where the WR-TDIF card is inserted can be selected as the wordclock source, in addition to the above-mentioned WCK IN. For WR-DA7 word- clock setting, press the D-I/O switch several times to display the INPUT SET screen of the D-I/O window. Then, select the SOURCE SELECT to the SLOT where the WR-TDIF card is installed.

The sampling rate settings for the DA-98, 88, 38 is dependent on the format of the tape being used. Therefore, the sampling rate is automatically selected according to the sample rate on the tape.

When the WR-DA7 is the wordclock master, the BNC cable should be connected from the WORD CLOCK OUT terminal of the WR-DA7 to the WORD SYNC IN terminal of the DA-98 or 38. Select WORD by pressing the CLOCK switch on the front panel of the DA-98 or 38.

When Connecting a DA-88 the WR-DA7 must function as the slave unit.

MIDI

For MMC control from the WR-DA7 to the DA-98, select Menu Group 3 in the DA-98 screen and select the Ctrl Prt (Control Protocol) to ‘MIDI.’

For the MIDI ID of MMC being received on the DA-98, select Menu Group 7 in the DA-98 screen and set the MIDI ID to the same number of the MIDI channel of the MMC to be sent from the WR- DA7.

Install the SY-88 Sync board to perform MMC operation from the

WR-DA7 to the DA88.

For SY-88 Sync board setting, set the MODE dip switch 2 on the rear panel at 0 (OFF) so that con- trol from external equipment can be accomplished through the MIDI port.

Timecode

When playing back the timecode recorded on the tape from the DA-98, select Menu Group 5 in the DA-98 screen and set Tape (ABS) with OutTc Src.

To generate the MTC output from the DA-98, select Menu Group 7 on the DA-98 screen and set the output to ‘ON’ with MTC Out. To generate the MTC output while the DA-98 is in FF/REW oper- ation, set fast to ‘ON.’ To generate the MTC output when the DA-98 is stopped, set Stop to ‘ON.’

To generate the timecode output from the DA-98 in synchronization with the digital audio data, select Menu Group 5 in the DA-98 screen and set ‘Digital’ with OutTc Tmg.

When an SY-88 Sync board is installed in the DA-88, it is possible to generate SMPTE timecode and MTC (MIDI timecode) from the DA-88.

For proper SY-88 Sync board setting, set the MODE dip switch 6 on the rear panel to 1 (ON) so that the timecode recorded on the tape of the DA-88 can be converted to MTC.

If the MODE dip switch 6 is set to 0 (OFF), the timecode received in the TIME CODE IN terminal of the DA-88 is then outputted after being converted to MTC.

To generate timecode from the DA-88 in synchronization with the digital audio data set the MODE dip switch 5 on the SY-88’s real panel to 0 (OFF).

10

Page 10
Image 10
Teac WR-DA7 manual Midi